Item


A CBR-based bolus recommender system for type 1 diabetes

People with type 1 diabetes mellitus usually need to administer bolus insulin before each meal to keep the blood glucose level in the target glycaemic range. However, the factors involved in the calculation of the appropriate dose can change due to multiple factors and with an unknown relation. This may increase the error in the bolus calculation, and therefore, increase the chances of hypoglycaemia and hyperglycaemia. This paper proposes a bolus recommender system based on case based reasoning developed under project PEPPER, with the objective of recommending personalised and adaptive bolus doses. The system has been tested with in silico adults with UVA/PADOVA T1DM simulator. Results show that the use of the proposed bolus recommender system increases the percentage of time in the target glycaemic range

Comunicaci贸 presentada a Workshop on Artificial Intelligence for Diabetes (2nd: 2017: Viena, 脌ustria)

This project has received funding from the grant of the University of Girona 2016-2018 (MPCUdG2016) and the European Union Horizon 2020 research and innovation programme under grant agreement No. 689810, www.pepper.eu.com/, PEPPER. The work has been developed with the support of the research group SITES awarded with distinction by the Generalitat de Catalunya (SGR 2014-2016).

漏 Herrero, P., L贸pez, B., Martin, C.(eds). (2017). AID 2017: Proceedings of the 2nd International Workshop on Artificial Intelligence for Diabetes held in conjunction with the 16th Conference on Artificial Intelligence in Medicine (AIME): Vienna, Austria: 24th June 2017, p. 9-14

Artificial Intelligence for Diabetes (AID)

Author: Torrent-Fontbona, Ferran
L贸pez Ib谩帽ez, Beatriz
Pozo-Alonso, Alejandro
Date: 2017
Abstract: People with type 1 diabetes mellitus usually need to administer bolus insulin before each meal to keep the blood glucose level in the target glycaemic range. However, the factors involved in the calculation of the appropriate dose can change due to multiple factors and with an unknown relation. This may increase the error in the bolus calculation, and therefore, increase the chances of hypoglycaemia and hyperglycaemia. This paper proposes a bolus recommender system based on case based reasoning developed under project PEPPER, with the objective of recommending personalised and adaptive bolus doses. The system has been tested with in silico adults with UVA/PADOVA T1DM simulator. Results show that the use of the proposed bolus recommender system increases the percentage of time in the target glycaemic range
Comunicaci贸 presentada a Workshop on Artificial Intelligence for Diabetes (2nd: 2017: Viena, 脌ustria)
This project has received funding from the grant of the University of Girona 2016-2018 (MPCUdG2016) and the European Union Horizon 2020 research and innovation programme under grant agreement No. 689810, www.pepper.eu.com/, PEPPER. The work has been developed with the support of the research group SITES awarded with distinction by the Generalitat de Catalunya (SGR 2014-2016).
Format: application/pdf
Document access: http://hdl.handle.net/10256/14318
Language: eng
Publisher: Artificial Intelligence for Diabetes (AID)
Collection: Reproducci贸 digital del document publicat a: http://sots.brookes.ac.uk/~p0042050/aid2017/assets/files/AIME_AID_2017_proceedings.pdf
Articles publicats (D-EEEiA)
info:eu-repo/grantAgreement/EC/H2020/689810
Is part of: 漏 Herrero, P., L贸pez, B., Martin, C.(eds). (2017). AID 2017: Proceedings of the 2nd International Workshop on Artificial Intelligence for Diabetes held in conjunction with the 16th Conference on Artificial Intelligence in Medicine (AIME): Vienna, Austria: 24th June 2017, p. 9-14