Ítem


Diagnosis, assessment and optimisation of the design and operation of municipal MBRs

This thesis is based on diagnosing, assessing and optimising the design and operation of membrane bioreactors (MBR) used for treating municipal wastewater. Specifically, this thesis has been carried out within the framework of seven municipal MBR wastewater treatment plants (WWTP) located in Catalonia with the collaboration of the Catalan Water Agency. Firstly, the design and operational issues of MBRs have been diagnosed, together with determining the main operational problems related to this technology. Secondly, the optimisation strategies applied in each full-scale MBR and the resulting costs were assessed. Finally, two of the operational problems identified were exhaustively evaluated: The ragging phenomenon and the biological nitrogen removal and operational costs optimisations. The research carried out in this thesis has enabled the design and operation of the municipal MBRs to be assessed while, at the same time, presenting several optimisation strategies which will improve the operation and costs of this technology

Aquesta tesi es centra en la diagnosi, avaluació i optimització del disseny i l’operació dels bioreactors de membranes (BRM) pel tractament d’aigües residuals. Concretament, l’estudi s’ha realitzat dins del marc de treball de set estacions depuradores d’aigües residuals (EDARs) municipals amb tecnologia BRM presents a Catalunya en col·laboració amb l’Agència Catalana de l’Aigua. Primerament s’ha dut a terme la diagnosi de l’estat del disseny i operació dels BRMs i s’han determinat les problemàtiques associades a aquesta tecnologia. Així mateix, s’han avaluat les estratègies d’optimització realitzades i els corresponents costos d’operació. A partir de la diagnosis realitzada, dos dels principals problemes operacionals observats s’han caracteritzat i optimitzat: El ragging i l’optimització de l’eliminació biològica de nitrogen i dels costos d’operació. La recerca presentada en aquesta tesi ha permès diagnosticar l’estat dels BRMs, alhora que ha mostrat possibles vies d’optimització que permetran millorar l’operació i els costos associats a aquesta tecnologia

Universitat de Girona

Director: Comas Matas, Joaquim
Rodríguez-Roda Layret, Ignasi
Altres contribucions: Universitat de Girona. Institut de Medi Ambient
Autor: Gabarrón Fernández, Sara
Data: 16 maig 2014
Resum: This thesis is based on diagnosing, assessing and optimising the design and operation of membrane bioreactors (MBR) used for treating municipal wastewater. Specifically, this thesis has been carried out within the framework of seven municipal MBR wastewater treatment plants (WWTP) located in Catalonia with the collaboration of the Catalan Water Agency. Firstly, the design and operational issues of MBRs have been diagnosed, together with determining the main operational problems related to this technology. Secondly, the optimisation strategies applied in each full-scale MBR and the resulting costs were assessed. Finally, two of the operational problems identified were exhaustively evaluated: The ragging phenomenon and the biological nitrogen removal and operational costs optimisations. The research carried out in this thesis has enabled the design and operation of the municipal MBRs to be assessed while, at the same time, presenting several optimisation strategies which will improve the operation and costs of this technology
Aquesta tesi es centra en la diagnosi, avaluació i optimització del disseny i l’operació dels bioreactors de membranes (BRM) pel tractament d’aigües residuals. Concretament, l’estudi s’ha realitzat dins del marc de treball de set estacions depuradores d’aigües residuals (EDARs) municipals amb tecnologia BRM presents a Catalunya en col·laboració amb l’Agència Catalana de l’Aigua. Primerament s’ha dut a terme la diagnosi de l’estat del disseny i operació dels BRMs i s’han determinat les problemàtiques associades a aquesta tecnologia. Així mateix, s’han avaluat les estratègies d’optimització realitzades i els corresponents costos d’operació. A partir de la diagnosis realitzada, dos dels principals problemes operacionals observats s’han caracteritzat i optimitzat: El ragging i l’optimització de l’eliminació biològica de nitrogen i dels costos d’operació. La recerca presentada en aquesta tesi ha permès diagnosticar l’estat dels BRMs, alhora que ha mostrat possibles vies d’optimització que permetran millorar l’operació i els costos associats a aquesta tecnologia
Format: application/pdf
Accés al document: http://hdl.handle.net/10803/145434
Llenguatge: eng
Editor: Universitat de Girona
Drets: ADVERTIMENT. L’accés als continguts d’aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d’investigació i docència en els termes establerts a l’art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l’autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s’autoritza la seva reproducció o altres formes d’explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d’un lloc aliè al servei TDX. Tampoc s’autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs.
Matèria: Enginyeria sanitària. Aigua. Sanejament. Enginyeria de la il·luminació
Títol: Diagnosis, assessment and optimisation of the design and operation of municipal MBRs
Tipus: doctoralThesis
Repositori: TDX

Matèries

Autors