Ítem


Thermal gradients in thermal analysis experiments: Criterions to prevent inaccuracies when determining sample temperature and kinetic parameters

Thermal analysis methods are customarily used to analyze the evolution of solid-state transformations when samples are submitted to a controlled temperature program. Thermal analysis results are generally interpreted under the assumption that no temperature gradients take place inside the sample, so that, under proper calibration the sample temperature can be determined and controlled. Two phenomena may contribute to the formation of temperature gradients within the sample: heat transport through the sample and heat evolved during an exothermic or endothermic transformation. We will provide two analytical relationships that relate the sample mass with the temperature gradient within the sample and that will provide a straightforward criterion for checking the reliability of the sample temperature. We will show that, because of their very low thermal conductivity, significant thermal gradients may occur in those samples in the form of powders. Besides, in the case of exothermic reactions and for typical experimental conditions, the heat released by the reaction significantly affects the determination of the sample temperature. Finally, we analyze how sample overheating affects the observed reaction kinetics

This work was partially funded by the Spanish Programa Nacional de Materiales through projects MAT2011-28874-C02-02 and by the Generalitat de Catalunya contract No. 2009SGR-185

Elsevier

Director: Ministerio de Ciencia e Innovación (Espanya)
Generalitat de Catalunya. Agència de Gestió d’Ajuts Universitaris i de Recerca
Autor: Sánchez-Rodríguez, Daniel
Eloussifi, Hichem
Farjas Silva, Jordi
Roura Grabulosa, Pere
Dammak, Mohamed Chedly
Resum: Thermal analysis methods are customarily used to analyze the evolution of solid-state transformations when samples are submitted to a controlled temperature program. Thermal analysis results are generally interpreted under the assumption that no temperature gradients take place inside the sample, so that, under proper calibration the sample temperature can be determined and controlled. Two phenomena may contribute to the formation of temperature gradients within the sample: heat transport through the sample and heat evolved during an exothermic or endothermic transformation. We will provide two analytical relationships that relate the sample mass with the temperature gradient within the sample and that will provide a straightforward criterion for checking the reliability of the sample temperature. We will show that, because of their very low thermal conductivity, significant thermal gradients may occur in those samples in the form of powders. Besides, in the case of exothermic reactions and for typical experimental conditions, the heat released by the reaction significantly affects the determination of the sample temperature. Finally, we analyze how sample overheating affects the observed reaction kinetics
This work was partially funded by the Spanish Programa Nacional de Materiales through projects MAT2011-28874-C02-02 and by the Generalitat de Catalunya contract No. 2009SGR-185
Accés al document: http://hdl.handle.net/2072/296636
Llenguatge: eng
Editor: Elsevier
Drets: Tots els drets reservats
Matèria: Anàlisi tèrmica
Thermal analysis
Calor -- Transmissió
Heat -- Transmission
Títol: Thermal gradients in thermal analysis experiments: Criterions to prevent inaccuracies when determining sample temperature and kinetic parameters
Tipus: info:eu-repo/semantics/article
Repositori: Recercat

Matèries

Autors