Ítem
Álvarez Puerta, Vicente
Aznar, F. Borges, Filipa I.G.M. Calvet, D. Cárcel García, Sara Castel, J. Cebrián, Susana Cervera Villanueva, Anselmo Conde, Carlos A.N Dafni, Theopisti Dias, T.H.V.T Díaz Medina, José Druillole, F. Egorov, M. Freitas, Elisabete D.C. Gehman, Victor M. Gil Ortiz, Alejandro Giomataris, I. Goldschmidt, Azriel Gómez, H. Gómez Cadenas, Juan González-Díaz, Diego Gutiérrez, Rafael María Hauptman, John M. Hernando Morata, J.A. Herrera, D.C. Iguaz, F.J. Irastorza, Igor Garcia Jinete, M.A. Labarga, Luis A. Laing, Andrew Le Coguie, A. Liubarsky, Igor Lopes, J.A.M. Lorca Galindo, David Losada, Marta Luzón, Gloria Marí, A. Martín-Albo Simón, Justo Martínez Pérez, Alberto Martínez Lema, Gonzalo Miller, Tom P. Moiseenko, A. Mols, J.P. Monrabal Capilla, Francesc Monteiro, Cristina M.B. Mora, Francisco José Moutinho, L.M. Muñoz Vidal, J. Natal da Luz, H. Navarro, G. Nebot Guinot, Miquel Nygren, David R. Oliveira, Carlos A.B. Palma, R. Pérez, Javier Martin Pérez Aparicio, J.L. Renner, Joshua Ripoll Masferrer, Lluís Rodríguez, Ángel Y. Rodríguez Samaniego, Javier Santos, Filomena P. dos Santos, Joaquim M.F. Seguí, Laura Serra Díaz-Cano, Luis Shuman, Derek B. Simón Estévez, Ander Sofka, C. Sorel, Michel Toledo, J.F. Tomás, A. Torrent Collell, Jordi Tsamalaidze, Zviadi Veloso, João F.C.A. Villar, José Ángel Webb, R.C. White, James T. Yahlali Haddou, Nadia |
|
15 febrer 2020 | |
A technical description of NEXT-MM and its commissioning and first performance is reported. Having an active volume of ~ 35 cm drift × 28 cm diameter, it constitutes the largest Micromegas-read TPC operated in Xenon ever constructed, made by a sectorial arrangement of the 4 largest single wafers manufactured with the Microbulk technique to date. It is equipped with a suitably pixelized readout and with a sufficiently large sensitive volume ( ~ 23 l) so as to contain long ( ~ 20 cm) electron tracks. First results obtained at 1 bar for Xenon and Trymethylamine (Xe-(2%)TMA) mixture are presented. The TPC can accurately reconstruct extended background tracks. An encouraging full-width half-maximum of 11.6 % was obtained for ~ 29 keV gammas without resorting to any data post-processing The NEXT Collaboration acknowledges funding support from the following agencies and institutions: the Spanish Ministerio de Economía y Competitividad under grants CONSOLIDERIngenio 2010 CSD2008-0037 (CUP), Consolider-Ingenio 2010 CSD2007- 00042 (CPAN), and under contracts ref. FPA2008-03456, FPA2009-13697-C04-04; FCT(Lisbon) and FEDER under grant PTDC/FIS/103860/2008; the European Commission under the European Research Council T-REX Starting Grant ref. ERC-2009-StG-240054 of the IDEAS program of the 7th EU Framework Program; Director, Office of Science, Office of Basic Energy Sciences, of the US Department of Energy under contract no. DE-AC02-05CH11231. Part of these grants are funded by the European Regional Development Fund (ERDF/FEDER). J. Renner (LBNL) acknowledges the support of a US DOE NNSA Stewardship Science Graduate Fellowship under contract no. DE-FC52-08NA28752 |
|
http://hdl.handle.net/2072/372196 | |
eng | |
Institute of Physics (IOP) | |
Tots els drets reservats | |
Enginyeria -- Instruments
Engineering instruments Detectors de radiació Nuclear counters |
|
Description and commissioning of NEXT-MM prototype: first results from operation in a Xenon-Trimethylamine gas mixture | |
info:eu-repo/semantics/article | |
Recercat |